A Industrial Gas Cogeneration plant uses natural gas as input fuel of the hot chamber to generate steam in order to produce electricity and heat. The thermal efficiency is 0.46 while the electrical efficiency is 0.44.

ES Model Parameters¤

All the parameters concerning the DHN Cogen Gas are listed in the table below.

entry_key value unit sets source_reference
CO2_A (layer) 0.430432 kt/GWh Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
ELECTRICITY_HV (layer) 0.9565 GWh Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
HEAT_HIGH_T (layer) 1 GWh Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
NG_MP (layer) -2.1739 GWh Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
c_inv 1503.64 MCHF/GW Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
c_maint 98.9 MCHF/GW/y Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
c_p 0.85 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
gwp_constr 1024.32 ktCO2_eq/GW Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
lifetime 25 y Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
ref_size 0.02 GW Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
trl 9 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"