Industrial Oil Boiler¤
Introduction¤
The Industrial Oil Boiler system uses a centralized Boiler to heat up water with Natural Gas as input fuel. The thermal efficiency of the Boiler is 0.873
ES Model Parameters¤
All the parameters concerning the DHN Boiler Oil are listed in the table below.
| entry_key | value | unit | sets | source_reference |
|---|---|---|---|---|
| CO2_A (layer) | 0.308085 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| HEAT_HIGH_T (layer) | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| LFO (layer) | -1.1461 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| c_inv | 58.58 | MCHF/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| c_maint | 1.26 | MCHF/GW/y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| c_p | 0.95 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| gwp_constr | 12.32 | ktCO2_eq/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| lifetime | 17 | y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| ref_size | 0.01 | GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| trl | 9 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" |
References¤
| Data Sources |
|---|
| Moret, Stefano. (2017). "Strategic Energy Planning under Uncertainty" |