DHN HP Elec¤
Introduction¤
District heating is a system for distributing heat from a centralized source to consumers via a network of underground insulated pipes carrying hot water. Centralized heat generation avoids the need for individual boilers or electric heaters in every building. A heat pump is a device transferring thermal energy from a heat source into a heat sink, absorbing heat from a cold space and releasing it into a warmer one using external power. This DHN heat pump technology considers a constant coefficient of performance of 4.
ES Model Parameters¤
All the parameters concerning the DHN HP Elec are listed in the table below.
| entry_key | value | unit | sets | source_reference |
|---|---|---|---|---|
| ELECTRICITY_MV (layer) | -0.25 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| HEAT_LOW_T_DHN (layer) | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| c_inv | 368.2 | MCHF/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| c_maint | 12.81 | MCHF/GW/yr | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| c_p | 0.95 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| gwp_constr | 174.8 | kgCO2/kWth | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| lifetime | 25 | y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| ref_size | 0.001 | GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
| trl | 9 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" |
References¤
| Data Sources |
|---|
| Moret, Stefano. (2017). "Strategic Energy Planning under Uncertainty" |