Industrial Direct Electricity Heating¤
Introduction¤
Direct electric heating refers to resistance heaters with fan assisted air circulation with a electric to thermal efficiency of 1.
ES Model Parameters¤
All the parameters concerning the Ind Direct Elec are listed in the table below.
entry_key | value | unit | sets | source_reference |
---|---|---|---|---|
ELECTRICITY_HV (layer) | -1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
HEAT_HIGH_T (layer) | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_inv | 354.91 | MCHF/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_maint | 1.61 | MCHF/GW/y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_p | 0.95 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
gwp_constr | 1.47 | ktCO2_eq/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
lifetime | 15 | y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
ref_size | 0.0001 | GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
trl | 9 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" |
References¤
Data Sources |
---|