Skip to content

Industrial Waste Cogeneration¤

Introduction¤

An Industrial Waste Cogeneration is based on a plant using waste as input fuel of the hot chamber to generate steam in order to produce electricity and heat.

ES Model Parameters¤

All the parameters concerning the DHN Cogen Waste are listed in the table below.

entry_key value unit sets source_reference
CO2_A (layer) 0.6913 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
ELECTRICITY_HV (layer) 0.4444 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
HEAT_HIGH_T (layer) 1 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
WASTE (layer) -2.2222 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
c_inv 3126.67 MCHF/GW Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
c_maint 118.88 MCHF/GW/y Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
c_p 0.85 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
gwp_constr 647.82 ktCO2_eq/GW Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
lifetime 25 y Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
ref_size 0.02 GW Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"
trl 9 - Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty"

References¤

Data Sources
Moret, Stefano. (2017). "Strategic Energy Planning under Uncertainty"

Parameters¤

References¤