Industrial Wood Cogeneration¤
Introduction¤
Cogeneration refers to the simultaneous generation of two useful products instead of only one. It consists of the use of a power station to generate electricity and heat at the same time, and is, in this case, called combined heat and power (CHP). An Industrial Wood Cogeneration plant uses wood as input fuel of the hot chamber to generate steam in order to produce electricity and heat. The thermal efficiency is 0.53 while the electrical efficiency is 0.18.
ES Model Parameters¤
All the parameters concerning the DHN Cogen Wood are listed in the table below.
entry_key | value | unit | sets | source_reference |
---|---|---|---|---|
CO2_A (layer) | 0.732522 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
ELECTRICITY_HV (layer) | 0.3396 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
HEAT_HIGH_T (layer) | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
WOOD (layer) | -1.8868 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_inv | 1154.18 | MCHF/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_maint | 43.24 | MCHF/GW/y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_p | 0.85 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
gwp_constr | 165.33 | ktCO2_eq/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
lifetime | 25 | y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
ref_size | 0.02 | GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
trl | 9 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" |
References¤
Data Sources |
---|
Moret, Stefano. (2017). "Strategic Energy Planning under Uncertainty" |