Decentralized Direct Electric Heating¤
Introduction¤
Direct electric heating refers to resistance heaters with fan assisted air circulation with a electric to thermal efficiency of 1. However, it is important to focus on the complete chain from the primary energy to the final one, considering all conversion devices in-between. For instance, if this electricity has been produced with a CCGT the efficiency will drop to 60%.
ES Model Parameters¤
All the parameters concerning the DEC Direct Elec. are listed in the table below.
entry_key | value | unit | sets | source_reference |
---|---|---|---|---|
ELECTRICITY_LV (layer) | -1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
HEAT_LOW_T_DECEN (layer) | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_inv | 42.7 | MCHF/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_maint | 0.19 | MCHF/GW/yr | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_p | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
gwp_constr | 1.5 | kgCO2/kWth | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
lifetime | 15 | y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
ref_size | 0.01 | GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
trl | 9 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" |
References¤
Data Sources |
---|
Moret, Stefano. (2017). "Strategic Energy Planning under Uncertainty" |