Decentralized Oil Boiler¤
Introduction¤
The LT DEC Gas Boiler technology uses light fuel oil as fuel input to produce heat with a thermal efficiency of 0.85. The amount of heat released by this technology depends on the heating value of the fuel (Oil LHV = 40-45 MJ/kg), the mass flow rate and the thermal efficiency.
ES Model Parameters¤
All the parameters concerning the DHN Boiler Oil Dec are listed in the table below.
entry_key | value | unit | sets | source_reference |
---|---|---|---|---|
CO2_E (layer) | 0.274295 | kt/GWh | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
HEAT_LOW_T_DECEN (layer) | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
LFO (layer) | -1.18 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_inv | 152.1 | MCHF/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_maint | 9.12 | MCHF/GW/yr | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_p | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
gwp_constr | 21.1 | kgCO2/kWth | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
lifetime | 17 | y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
ref_size | 0.01 | GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
trl | 9 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" |
References¤
Data Sources |
---|
Moret, Stefano. (2017). "Strategic Energy Planning under Uncertainty" |