DHN Deep Geothermal¤
Introduction¤
District heating is a system for distributing heat from a centralized source to consumers via a network of underground insulated pipes carrying hot water. Centralized heat generation avoids the need for individual boilers or electric heaters in every building. This technology considers the direct use of a Geothermal well at 4.2 km depth for district heating application.
ES Model Parameters¤
All the parameters concerning the DHN Deep Geoth. are listed in the table below.
entry_key | value | unit | sets | source_reference |
---|---|---|---|---|
HEAT_LOW_T_DHN (layer) | 1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
RES_GEO (layer) | -1 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_inv | 1620.1 | MCHF/GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_maint | 60.12 | MCHF/GW/yr | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
c_p | 0.85 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
gwp_constr | 808.8 | kgCO2/kWth | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
lifetime | 30 | y | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
ref_size | 0.023 | GW | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" | |
trl | 9 | - | Moret, Stefano, (2017): "Strategic Energy Planning under Uncertainty" |
References¤
Data Sources |
---|
Moret, Stefano. (2017). "Strategic Energy Planning under Uncertainty" |